Model NO.: ASTM B232
Brand: Henan Jiapu Cable
Cross Section Area: <1250mm2
Conductor Type: Aluminium
Structure: Stranded
Material: Aluminiun 1350
Voltage Rating: From Extra High Voltage to Utilization Voltages on
No.of Wire: 1-91
Trademark: Jiapu
Transport Package: Wooden Drums
Specification: ACSR
Origin: Henan China
HS Code: 7614100000
Model NO.: ASTM B232
Brand: Henan Jiapu Cable
Cross Section Area: <1250mm2
Conductor Type: Aluminium
Structure: Stranded
Material: Aluminiun 1350
Voltage Rating: From Extra High Voltage to Utilization Voltages on
No.of Wire: 1-91
Trademark: Jiapu
Transport Package: Wooden Drums
Specification: ACSR
Origin: Henan China
HS Code: 7614100000
AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
 Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
 Relative manufacturing standards:
IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Packing:
Standard export wooden drums
Standards | IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 |
Certificate | ISO 9001 and ISO 14001. CE ,SONCAP |
Type | AAC, AAAC, ACSR, AACSR&ACAR conductor |
AAC | AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. |
AAAC | (AAAC) Conductor as per ASTM-B-399-1992 |
ACSR | ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) |
Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
Â
Property:
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
 Â
Standard:
 Â
ASTM B230,B231,B400 Standard
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
AWG or MCM |
mm |
mm |
ohm/km |
AWG or MCM |
mm |
mm |
ohm/km |
||
Peachbell |
6 |
7/1.554 |
4.67 |
2.1692 |
Verbena |
700 |
37/3.493 |
24.45 |
0.0813 |
Rose |
4 |
7/1.961 |
5.89 |
1.3624 |
Nasturtium |
715.5 |
61/2.75 |
24.76 |
0.0795 |
Lris |
2 |
7/2.474 |
7.42 |
0.8577 |
Violet |
715.5 |
37/3.533 |
24.74 |
0.0795 |
Pansey |
1 |
7/2.776 |
8.33 |
0.6801 |
Cattail |
750 |
61/2.817 |
25.35 |
0.0759 |
Poppy |
1/0 |
7/3.119 |
9.36 |
0.5390 |
Petunia |
750 |
37/3.617 |
25.32 |
0.0759 |
Aster |
2/0 |
7/3.503 |
10.51 |
0.4276 |
Lilac |
795 |
61/2.90 |
26.11 |
0.0715 |
Phlox |
3/0 |
7/3.932 |
11.80 |
0.3390 |
Arbutus |
795 |
37/3.724 |
26.06 |
0.0715 |
Oxlip |
4/0 |
7/4.417 |
13.26 |
0.2688 |
Snapdragon |
900 |
61/3.086 |
27.78 |
0.0632 |
Valerian |
250 |
19/2.913 |
14.57 |
0.2275 |
Cockscomb |
900 |
37/3.962 |
27.73 |
0.0632 |
Sneezewort |
250 |
7/4.80 |
14.4 |
0.2275 |
Goldenrod |
954 |
61/3.177 |
28.6 |
0.0596 |
Laurel |
266.8 |
19/3.01 |
15.05 |
0.2133 |
Magnolia |
954 |
37/4.079 |
28.55 |
0.0596 |
Daisy |
266.8 |
7/4.96 |
14.9 |
0.2133 |
Camellia |
1000 |
61/3.251 |
29.36 |
0.0569 |
Peony |
300 |
19/3.193 |
15.97 |
0.1896 |
Hawkweed |
1000 |
37/4.176 |
29.23 |
0.0569 |
Tulip |
336.4 |
19/3.381 |
16.91 |
0.1691 |
Larkspur |
1033.5 |
61/3.307 |
29.76 |
0.0550 |
Daffodil |
350 |
19/3.447 |
17.24 |
0.1625 |
Bluebell |
1033.5 |
37/4.244 |
29.72 |
0.0550 |
Canna |
397.5 |
19/3.673 |
18.36 |
0.1431 |
Marigold |
1113 |
61/3.432 |
30.89 |
0.0511 |
Goldentuft |
450 |
19/3.909 |
19.55 |
0.1264 |
Hawthorn |
1192.5 |
61/3.551 |
31.05 |
0.0477 |
Syringa |
477 |
37/2.882 |
20.19 |
0.1193 |
Narcissus |
1272 |
61/3.668 |
33.02 |
0.0477 |
Cosmos |
477 |
19/4.023 |
20.12 |
0.1193 |
Columbine |
1351.5 |
61/3.78 |
34.01 |
0.0421 |
Hyacinth |
500 |
37/2.951 |
20.65 |
0.1138 |
Carnation |
1431 |
61/3.89 |
35.03 |
0.0398 |
Zinnia |
500 |
19/4.12 |
20.6 |
0.1138 |
Gladiolus |
1510.5 |
61/4.00 |
35.09 |
0.0376 |
Dahlia |
556.5 |
19/4.346 |
21.73 |
0.1022 |
Coreopsis |
1590 |
61/4.099 |
36.51 |
0.03568 |
Mistletoe |
556.5 |
37/3.114 |
21.79 |
0.1022 |
Jessamine |
1750 |
61/4.302 |
38.72 |
0.0325 |
Meadowsweet |
600 |
37/3.233 |
22.63 |
0.0948 |
Cowslip |
2000 |
91/3.76 |
41.40 |
0.02866 |
Orchid |
636 |
37/3.33 |
23.31 |
0.0894 |
Lupine |
2500 |
91/4.21 |
46.30 |
0.0230 |
Heuchera |
650 |
37/3.366 |
23.56 |
0.0875 |
Trillium |
3000 |
127/3.90 |
50.75 |
0.0192 |
Flag |
700 |
61/2.72 |
24.48 |
0.0813 |
Bluebonnet |
3500 |
127/4.21 |
54.80 |
0.01653 Â |
Workshop:
Shipment:
Â
Customer:
Â
Certification:
Â
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.Â
8. Do you supply the customers with installation service in foreign country ?
We don't have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
 Â
 AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
 Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
 Relative manufacturing standards:
IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Packing:
Standard export wooden drums
Standards | IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 |
Certificate | ISO 9001 and ISO 14001. CE ,SONCAP |
Type | AAC, AAAC, ACSR, AACSR&ACAR conductor |
AAC | AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. |
AAAC | (AAAC) Conductor as per ASTM-B-399-1992 |
ACSR | ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) |
Application
The conductors are suitable for use in spans on wood poles, transmission towers,and other structures where tensile strength and temperature ratings are not required. Application range from extra high voltage(EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. AAC(All aluminum conductor) is the most economical bare overhead conductor due to its lighter weight. It offers easier handing during installation and use of simpler fittings. The conductor is corrosion resistant due to its homogeneous construction.
Â
Property:
Aluminum 1350 wires are concentrically stranded and wrapped helically around a central wire. Each successive layer has six wires more than the previous underlying layer. Outer layer is right hand lay and reversed in successive layers.
 Â
Standard:
 Â
ASTM B230,B231,B400 Standard
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
Code word |
Size of Conductor |
Stranding and Wire Diameter |
Overall Diameter |
Max.D.C. Resistance at 20°C |
AWG or MCM |
mm |
mm |
ohm/km |
AWG or MCM |
mm |
mm |
ohm/km |
||
Peachbell |
6 |
7/1.554 |
4.67 |
2.1692 |
Verbena |
700 |
37/3.493 |
24.45 |
0.0813 |
Rose |
4 |
7/1.961 |
5.89 |
1.3624 |
Nasturtium |
715.5 |
61/2.75 |
24.76 |
0.0795 |
Lris |
2 |
7/2.474 |
7.42 |
0.8577 |
Violet |
715.5 |
37/3.533 |
24.74 |
0.0795 |
Pansey |
1 |
7/2.776 |
8.33 |
0.6801 |
Cattail |
750 |
61/2.817 |
25.35 |
0.0759 |
Poppy |
1/0 |
7/3.119 |
9.36 |
0.5390 |
Petunia |
750 |
37/3.617 |
25.32 |
0.0759 |
Aster |
2/0 |
7/3.503 |
10.51 |
0.4276 |
Lilac |
795 |
61/2.90 |
26.11 |
0.0715 |
Phlox |
3/0 |
7/3.932 |
11.80 |
0.3390 |
Arbutus |
795 |
37/3.724 |
26.06 |
0.0715 |
Oxlip |
4/0 |
7/4.417 |
13.26 |
0.2688 |
Snapdragon |
900 |
61/3.086 |
27.78 |
0.0632 |
Valerian |
250 |
19/2.913 |
14.57 |
0.2275 |
Cockscomb |
900 |
37/3.962 |
27.73 |
0.0632 |
Sneezewort |
250 |
7/4.80 |
14.4 |
0.2275 |
Goldenrod |
954 |
61/3.177 |
28.6 |
0.0596 |
Laurel |
266.8 |
19/3.01 |
15.05 |
0.2133 |
Magnolia |
954 |
37/4.079 |
28.55 |
0.0596 |
Daisy |
266.8 |
7/4.96 |
14.9 |
0.2133 |
Camellia |
1000 |
61/3.251 |
29.36 |
0.0569 |
Peony |
300 |
19/3.193 |
15.97 |
0.1896 |
Hawkweed |
1000 |
37/4.176 |
29.23 |
0.0569 |
Tulip |
336.4 |
19/3.381 |
16.91 |
0.1691 |
Larkspur |
1033.5 |
61/3.307 |
29.76 |
0.0550 |
Daffodil |
350 |
19/3.447 |
17.24 |
0.1625 |
Bluebell |
1033.5 |
37/4.244 |
29.72 |
0.0550 |
Canna |
397.5 |
19/3.673 |
18.36 |
0.1431 |
Marigold |
1113 |
61/3.432 |
30.89 |
0.0511 |
Goldentuft |
450 |
19/3.909 |
19.55 |
0.1264 |
Hawthorn |
1192.5 |
61/3.551 |
31.05 |
0.0477 |
Syringa |
477 |
37/2.882 |
20.19 |
0.1193 |
Narcissus |
1272 |
61/3.668 |
33.02 |
0.0477 |
Cosmos |
477 |
19/4.023 |
20.12 |
0.1193 |
Columbine |
1351.5 |
61/3.78 |
34.01 |
0.0421 |
Hyacinth |
500 |
37/2.951 |
20.65 |
0.1138 |
Carnation |
1431 |
61/3.89 |
35.03 |
0.0398 |
Zinnia |
500 |
19/4.12 |
20.6 |
0.1138 |
Gladiolus |
1510.5 |
61/4.00 |
35.09 |
0.0376 |
Dahlia |
556.5 |
19/4.346 |
21.73 |
0.1022 |
Coreopsis |
1590 |
61/4.099 |
36.51 |
0.03568 |
Mistletoe |
556.5 |
37/3.114 |
21.79 |
0.1022 |
Jessamine |
1750 |
61/4.302 |
38.72 |
0.0325 |
Meadowsweet |
600 |
37/3.233 |
22.63 |
0.0948 |
Cowslip |
2000 |
91/3.76 |
41.40 |
0.02866 |
Orchid |
636 |
37/3.33 |
23.31 |
0.0894 |
Lupine |
2500 |
91/4.21 |
46.30 |
0.0230 |
Heuchera |
650 |
37/3.366 |
23.56 |
0.0875 |
Trillium |
3000 |
127/3.90 |
50.75 |
0.0192 |
Flag |
700 |
61/2.72 |
24.48 |
0.0813 |
Bluebonnet |
3500 |
127/4.21 |
54.80 |
0.01653 Â |
Workshop:
Shipment:
Â
Customer:
Â
Certification:
Â
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cabl
Medical Actuator
Medical series mainly apply for medical equipment, such as hospital bed, dental chair, rehabilitation training equipment, etc. They are very quiet so that you can barely notice it. More than 4 models are available for different requirements. Max. load ranges from 6,000N to 12,000N. There are different controllers to be chosen, including handset and control box.
Medical Care Actuator,Electric Linear Actuator,Actuator For Patient Lift,Dc Medical Care Actuator
TOMUU (DONGGUAN) ACTUATOR TECHNOLOGY CO., LTD. , http://www.tomuu.com