Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2

Model NO.: Al/XLPE/PVC
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, SGS
Model: Yjlv
Brand: Hongda
Standard: IEC 60502
No. of Cores: 1 Core, 2 Cores, 3 Cores, 4 Cores, 5 Cores
Armour: Aluminum/Galvanized Steel/Steel Wires
Trademark: Hongda, accept OEM
Transport Package: Steel & Wooden Drum or Customer Requirement
Specification: 10 sqmm to 300 sqmm
Origin: China
HS Code: 8544492100
Model NO.: Al/XLPE/PVC
Wire Core Material: Red Copper Wire
Certification: ISO, CCC, SGS
Model: Yjlv
Brand: Hongda
Standard: IEC 60502
No. of Cores: 1 Core, 2 Cores, 3 Cores, 4 Cores, 5 Cores
Armour: Aluminum/Galvanized Steel/Steel Wires
Trademark: Hongda, accept OEM
Transport Package: Steel & Wooden Drum or Customer Requirement
Specification: 10 sqmm to 300 sqmm
Origin: China
HS Code: 8544492100

Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2

Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction:
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2
 
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2
Conductor: annealed copper or of plain aluminium or aluminium alloy
Insulation: XLPE / PVC material
Armour: 
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
Sheath: PVC compound
sheath colour: black

Technical data:
Temperature range:  
during installation: -5 °C up to +50 °C
fixed installed: -30 °C up to +70 °C
at short circuit of max. 5 s: up to 160 °C
Nominal voltage: Uο/U = 0,6/1 kV
Test voltage: 4 kV
Max. operating voltage in three-phase systems: 1,2 kV
Maximal tensile strength: 50 N/mm²
Behaviour in fire: IEC 60332-1
Minimal inner bending radius:  
single core: 15D
multi core: 12D
 
Dimensions:

Single core(unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1x1.5 1.4 0.7 1.4 5.6
1x2.5 1.8 0.7 1.4 6.0
1x4 2.3 0.7 1.4 6.5
1x6 2.8 0.7 1.4 7.0
1x10 3.6 0.7 1.4 7.8
1x16 4.5 0.7 1.4 8.7
1x25 5.6 0.9 1.4 10.2
1x35 6.7 0.9 1.4 11.3
1x50 8.0 1 1.4 12.8
1x70 9.4 1.1 1.4 14.4
1x95 11.0 1.1 1.5 16.1
1x120 12.4 1.2 1.5 17.8
1x150 13.8 1.4 1.6 19.8
1x185 15.3 1.6 1.6 21.8
1x240 17.5 1.7 1.7 24.4
1x300 19.5 1.8 1.8 26.7
1x400 22.6 2 1.9 30.5
1x500 25.2 2.2 2.0 33.7
1x630 28.3 2.4 2.2 37.4
1x800 31.9 2.6 2.3 41.7
1x1000 35.7 2.8 2.4 46.2

Two cores(unarmoured)
 
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2x1.5 1.4 0.7 1.8 9.2
2x2.5 1.8 0.7 1.8 10.0
2x4 2.3 0.7 1.8 11.0
2x6 2.8 0.7 1.8 12.0
2x10 3.6 0.7 1.8 13.6
2x16 4.5 0.7 1.8 15.4
2x25 5.6 0.9 1.8 18.4
2x35 6.7 0.9 1.8 20.6
2x50 8.0 1 1.8 23.6
2x70 9.4 1.1 1.8 26.8
2x95 11.0 1.1 1.9 30.2
2x120 12.4 1.2 2.0 33.7
2x150 13.8 1.4 2.2 37.5
2x185 15.3 1.6 2.3 41.6
2x240 17.5 1.7 2.5 46.7
2x300 19.5 1.8 2.6 51.4
2x400 22.6 2 2.9 58.9

Three cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3x1.5 1.4 0.7 1.8 9.6
3x2.5 1.8 0.7 1.8 10.5
3x4 2.3 0.7 1.8 11.6
3x6 2.8 0.7 1.8 12.6
3x10 3.6 0.7 1.8 14.4
3x16 4.5 0.7 1.8 16.3
3x25 5.6 0.9 1.8 19.5
3x35 6.7 0.9 1.8 21.9
3x50 8.0 1 1.8 25.1
3x70 9.4 1.1 1.9 28.7
3x95 11.0 1.1 2.0 32.4
3x120 12.4 1.2 2.1 36.1
3x150 13.8 1.4 2.3 40.3
3x185 15.3 1.6 2.4 44.6
3x240 17.5 1.7 2.6 50.2
3x300 19.5 1.8 2.7 55.2
3x400 22.6 2 3.0 63.3

Three cores+1(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3x120/70 12.4 9.4 1.2 1.1 2.3 39.9
3x150/70 13.8 9.4 1.4 1.1 2.4 44.6
3x185/95 15.3 11 1.6 1.1 2.6 49.5
3x240/120 17.5 12.4 1.7 1.2 2.8 55.7
3x300/150 19.5 13.8 1.8 1.4 3.0 61.4
3x400/185 22.6 15.3 2 1.6 3.2 70.4

Four cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4x1.5 1.4 0.7 1.8 10.4
4x2.5 1.8 0.7 1.8 11.3
4x4 2.3 0.7 1.8 12.5
4x6 2.8 0.7 1.8 13.7
4x10 3.6 0.7 1.8 15.7
4x16 4.5 0.7 1.8 17.8
4x25 5.6 0.9 1.8 21.5
4x35 6.7 0.9 1.8 24.1
4x50 8.0 1 1.8 27.8
4x70 9.4 1.1 2.0 32.0
4x95 11.0 1.1 2.1 36.1
4x120 12.4 1.2 2.3 40.2
4x150 13.8 1.4 2.4 44.9
4x185 15.3 1.6 2.6 49.8
4x240 17.5 1.7 2.8 56.0
4x300 19.5 1.8 3.0 61.7
4x400 22.6 2 3.2 70.7

Multi-cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5x1.5 1.4 0.7 1.8 11.2
7x1.5 1.4 0.7 1.8 12.0
10x1.5 1.4 0.7 1.8 14.8
12x1.5 1.4 0.7 1.8 15.2
14x1.5 1.4 0.7 1.8 16.0
19x1.5 1.4 0.7 1.8 17.6
21x1.5 1.4 0.7 1.8 18.4
24x1.5 1.4 0.7 1.8 20.4
30x1.5 1.4 0.7 1.8 21.6
40x1.5 1.4 0.7 1.8 26.0
48x1.5 1.4 0.7 1.8 26.4
61x1.5 1.4 0.7 1.9 29.0
5x2.5 1.8 0.7 1.8 12.2
7x2.5 1.8 0.7 1.8 13.2
10x2.5 1.8 0.7 1.8 16.4
12x2.5 1.8 0.7 1.8 16.9
14x2.5 1.8 0.7 1.8 17.7
19x2.5 1.8 0.7 1.8 19.6
21x2.5 1.8 0.7 1.8 20.6
24x2.5 1.8 0.7 1.8 22.8
30x2.5 1.8 0.7 1.8 24.1
40x2.5 1.8 0.7 1.9 29.4
48x2.5 1.8 0.7 1.9 29.9
61x2.5 1.8 0.7 2.0 32.8

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length.

COMPANY INFORMATION:
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2


For more information and inquiry, pls contact me without any hesitation.
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2

Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2

Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction:
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2
 
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2
Conductor: annealed copper or of plain aluminium or aluminium alloy
Insulation: XLPE / PVC material
Armour: 
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
Sheath: PVC compound
sheath colour: black

Technical data:
Temperature range:  
during installation: -5 °C up to +50 °C
fixed installed: -30 °C up to +70 °C
at short circuit of max. 5 s: up to 160 °C
Nominal voltage: Uο/U = 0,6/1 kV
Test voltage: 4 kV
Max. operating voltage in three-phase systems: 1,2 kV
Maximal tensile strength: 50 N/mm²
Behaviour in fire: IEC 60332-1
Minimal inner bending radius:  
single core: 15D
multi core: 12D
 
Dimensions:

Single core(unarmoured)

Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
1x1.5 1.4 0.7 1.4 5.6
1x2.5 1.8 0.7 1.4 6.0
1x4 2.3 0.7 1.4 6.5
1x6 2.8 0.7 1.4 7.0
1x10 3.6 0.7 1.4 7.8
1x16 4.5 0.7 1.4 8.7
1x25 5.6 0.9 1.4 10.2
1x35 6.7 0.9 1.4 11.3
1x50 8.0 1 1.4 12.8
1x70 9.4 1.1 1.4 14.4
1x95 11.0 1.1 1.5 16.1
1x120 12.4 1.2 1.5 17.8
1x150 13.8 1.4 1.6 19.8
1x185 15.3 1.6 1.6 21.8
1x240 17.5 1.7 1.7 24.4
1x300 19.5 1.8 1.8 26.7
1x400 22.6 2 1.9 30.5
1x500 25.2 2.2 2.0 33.7
1x630 28.3 2.4 2.2 37.4
1x800 31.9 2.6 2.3 41.7
1x1000 35.7 2.8 2.4 46.2

Two cores(unarmoured)
 
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
2x1.5 1.4 0.7 1.8 9.2
2x2.5 1.8 0.7 1.8 10.0
2x4 2.3 0.7 1.8 11.0
2x6 2.8 0.7 1.8 12.0
2x10 3.6 0.7 1.8 13.6
2x16 4.5 0.7 1.8 15.4
2x25 5.6 0.9 1.8 18.4
2x35 6.7 0.9 1.8 20.6
2x50 8.0 1 1.8 23.6
2x70 9.4 1.1 1.8 26.8
2x95 11.0 1.1 1.9 30.2
2x120 12.4 1.2 2.0 33.7
2x150 13.8 1.4 2.2 37.5
2x185 15.3 1.6 2.3 41.6
2x240 17.5 1.7 2.5 46.7
2x300 19.5 1.8 2.6 51.4
2x400 22.6 2 2.9 58.9

Three cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
3x1.5 1.4 0.7 1.8 9.6
3x2.5 1.8 0.7 1.8 10.5
3x4 2.3 0.7 1.8 11.6
3x6 2.8 0.7 1.8 12.6
3x10 3.6 0.7 1.8 14.4
3x16 4.5 0.7 1.8 16.3
3x25 5.6 0.9 1.8 19.5
3x35 6.7 0.9 1.8 21.9
3x50 8.0 1 1.8 25.1
3x70 9.4 1.1 1.9 28.7
3x95 11.0 1.1 2.0 32.4
3x120 12.4 1.2 2.1 36.1
3x150 13.8 1.4 2.3 40.3
3x185 15.3 1.6 2.4 44.6
3x240 17.5 1.7 2.6 50.2
3x300 19.5 1.8 2.7 55.2
3x400 22.6 2 3.0 63.3

Three cores+1(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 (3)mm (1)mm (3)mm (1)mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1.8 17.5
3x 25/16 5.6 4.5 0.9 0.7 1.8 21.2
3x 35/16 6.7 4.5 0.9 0.7 1.8 23.8
3x 50/25 8 5.6 1 0.9 1.8 27.5
3x 70/35 9.4 6.7 1.1 0.9 2.0 31.7
3x 95/50 11 8 1.1 1 2.1 35.8
3x120/70 12.4 9.4 1.2 1.1 2.3 39.9
3x150/70 13.8 9.4 1.4 1.1 2.4 44.6
3x185/95 15.3 11 1.6 1.1 2.6 49.5
3x240/120 17.5 12.4 1.7 1.2 2.8 55.7
3x300/150 19.5 13.8 1.8 1.4 3.0 61.4
3x400/185 22.6 15.3 2 1.6 3.2 70.4

Four cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
4x1.5 1.4 0.7 1.8 10.4
4x2.5 1.8 0.7 1.8 11.3
4x4 2.3 0.7 1.8 12.5
4x6 2.8 0.7 1.8 13.7
4x10 3.6 0.7 1.8 15.7
4x16 4.5 0.7 1.8 17.8
4x25 5.6 0.9 1.8 21.5
4x35 6.7 0.9 1.8 24.1
4x50 8.0 1 1.8 27.8
4x70 9.4 1.1 2.0 32.0
4x95 11.0 1.1 2.1 36.1
4x120 12.4 1.2 2.3 40.2
4x150 13.8 1.4 2.4 44.9
4x185 15.3 1.6 2.6 49.8
4x240 17.5 1.7 2.8 56.0
4x300 19.5 1.8 3.0 61.7
4x400 22.6 2 3.2 70.7

Multi-cores(unarmoured)
Nominal Cross Section Diameter of Conductor (Approx.) Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter (Approx.)
mm^2 mm mm mm mm
5x1.5 1.4 0.7 1.8 11.2
7x1.5 1.4 0.7 1.8 12.0
10x1.5 1.4 0.7 1.8 14.8
12x1.5 1.4 0.7 1.8 15.2
14x1.5 1.4 0.7 1.8 16.0
19x1.5 1.4 0.7 1.8 17.6
21x1.5 1.4 0.7 1.8 18.4
24x1.5 1.4 0.7 1.8 20.4
30x1.5 1.4 0.7 1.8 21.6
40x1.5 1.4 0.7 1.8 26.0
48x1.5 1.4 0.7 1.8 26.4
61x1.5 1.4 0.7 1.9 29.0
5x2.5 1.8 0.7 1.8 12.2
7x2.5 1.8 0.7 1.8 13.2
10x2.5 1.8 0.7 1.8 16.4
12x2.5 1.8 0.7 1.8 16.9
14x2.5 1.8 0.7 1.8 17.7
19x2.5 1.8 0.7 1.8 19.6
21x2.5 1.8 0.7 1.8 20.6
24x2.5 1.8 0.7 1.8 22.8
30x2.5 1.8 0.7 1.8 24.1
40x2.5 1.8 0.7 1.9 29.4
48x2.5 1.8 0.7 1.9 29.9
61x2.5 1.8 0.7 2.0 32.8

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length.

COMPANY INFORMATION:
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2


For more information and inquiry, pls contact me without any hesitation.
Single Core Unarmoured Al/XLPE/PVC Cover Electric Power Cable 300mm2

ATX Power Supply

Power Supply,Atx Power Supply,Switching Power Supply